Use dedicated function for calculating stack usage of the
interrupt stack(s).
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Add option to include analysis of interrupt stack(s) when
threads are analyzed.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
There is no releavnce between CAN sockets and offloading that would
prevent one from working with another, therefore it's not right to
allow CAN sockets to be build only if offloading is disabled. Fix the
wrong dependency in socket CMakeLists.txt file.
Signed-off-by: Robert Lubos <robert.lubos@nordicsemi.no>
Added a missing assert statement for validation of the preferred
supervision timeout parameter which can be configured by the user
via Kconfig.
Signed-off-by: Kamil Piszczek <Kamil.Piszczek@nordicsemi.no>
Minor improvement: Use already existing variable, rather than finding
the same value again. It is clearer, and simpler, to use the variable
everywhere this value is needed.
Signed-off-by: Asbjørn Sæbø <asbjorn.sabo@nordicsemi.no>
Avoids copying the address and assigning the SID if the
PA list is used, as the values are ignored by the
controller, and thus there is no reason to copy
or assign the values.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
The smp_process_request_packet has been checking return code from
mgmt_streamer_init_writer where Zephyr implementation of the
callback always returns 0.
Signed-off-by: Dominik Ermel <dominik.ermel@nordicsemi.no>
Fix bug in radio implementation that reported any transmit error
as `OT_ERROR_NO_ACK` to OpenThread.
Signed-off-by: Eduardo Montoya <eduardo.montoya@nordicsemi.no>
This is to support Sypnosys Designware SDMMC controller read and write
operation where the buffer address is needed to be 16bytes and 512bytes
aligned. Adding macro FS_FATFS_WINDOW_ALIGNMENT to align the "win"
variable address in FATFS struct.
Signed-off-by: Boon Khai Ng <boon.khai.ng@intel.com>
This solves the following issues:
- Auto-initiation of commands is aborted if one of the issued commands
fails
- The controller return value for a PHY update or DL update is not
made available to the application.
As a result, the host no longer prevents the application from calling
bt_conn_le_data_len_update() and bt_conn_le_phy_update() before the
auto-initiated procedure completes. Now the controller may or may not
accept the additional command issued by the application.
It also simplifies the code:
- We no longer need to keep track of if the auto-phy update
or auto-dl update has completed. If the controller receives
another LE Set PHY while the procedure is pending in the LL, it can
decide if wants to accept another procedure initiation or not.
- We no longer need to auto-initiate auto-initiation of commands in
multiple places
Signed-off-by: Rubin Gerritsen <rubin.gerritsen@nordicsemi.no>
Logging v2 did not support getting memory usage data. Adding this
support by creating common api for getting current and maximum
usage. Tracking of maximum usage is optional and can be enabled
using CONFIG_LOG_MEM_UTILIZATION.
Updated shell command to use common API.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
There were some references to slave and master left in the unittests
for the refactored LLCP.
These are changed in respectively peripheral and central
Signed-off-by: Andries Kruithof <Andries.Kruithof@nordicsemi.no>
Tests that when a collision happens, the connection attempt is retried
and that it succeeds.
Signed-off-by: Herman Berget <herman.berget@nordicsemi.no>
The iso_rx_pool did not use the correct buffer size due to
a missing BT_ISO_SDU_BUF_SIZE, causing it to be too small.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
Ensure that ISO-TP Consecutive Frames (CF) are sent in
FIFO/chronological order.
In order to ensure this, we can only have one CF queued in the CAN
controller TX mailboxes at a time, since transmit order for mailboxes
with the same CAN-ID (priority) is hardware specific.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Firmware uploading to the host may not always be desired,
disable it by default.
Enable it for existing USB DFU sample to keep
the usual behavior, add note about new option to README.rst.
Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
Rename confusing UPLOAD_FLASH_AREA_ID to DOWNLOAD_FLASH_AREA_ID
as it is area where firmware image is downloaded.
Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
It is possible that the actual data stage length of
the control transfer is zero, in that case we do not
need an additional ZLP packet.
This fixes a problem with USB DFU, where after an upload
the device is no longer responsive if upload size is
multiple of control endpoint MPS.
Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
Fix an issue where a test's suite name was misspelled and thus the
test never ran because it wasn't associated with a suite. Example:
ZTEST_SUITE(my_suite, NULL, NULL, NULL, NULL, NULL);
ZTEST(myy_suite, test)
{
}
The above will no longer pass since `myy_suite` with a double `y` will
fail the verification.
Signed-off-by: Yuval Peress <peress@google.com>
This fix a typo where incorrect member of bt_keys was used for
checking if LTK is present. This was resulting in bogus results
depending on connection role and current identity used.
This was affecting L2CAP/LE/CFC/BV-25-C qualification test case.
Fixes: #42862
Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl>
Periodic advertising sync may be created with CTE type filtering
enabled. When received AUX_SYNC_IND, there are HCI_LE_Periodic_-
Advertising_Sync_Established and HCI_LE_Periodic_Advertising_Report
events generated. In case received AUX_SYNC_IND has wrong CTE type,
HCI_LE_Periodic_Advertising_Sync_Established event is generated.
There may not be HCI_LE_Periodic_Advertising_Report event generated.
In this case node_rx, prepared by LLL, was not released in ULL.
It was lost in ull_sync_established_report.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
CONFIG_BT_CTLR_DF_CTE_RX is enabled by default if CONFIG_BT_CLTR_DF
is enabled and there is support for DF in given SOC.
If CONFIG_BT_CTLR_DF_SCAN_CTE_RX is disabled then the CONFIG_BT_CTLR-
_PER_SCAN_CTE_NUM_MAX is not available.
It causes build errors if that particular configuration is used by
an application. It was a case for example in split builds of direction
finding connectionless TX sample application were periodic advertising
was enabled but perddioc advertising sync was disabled.
The commit fixes the problem.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
Previously the data was set incorrectly when the data was set in
multiple operations. It did not take the previous state into account.
Fixes: https://github.com/zephyrproject-rtos/zephyr/issues/42648
Signed-off-by: Rubin Gerritsen <rubin.gerritsen@nordicsemi.no>
There were used an uninitialized variable to set antenna identifiers
length. The value should be set with use of params argument, not
by cp pointer that is not yet initialized.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
Fix to use non-discardable Rx buffer for handling Extended
and Periodic Advertising Report.
Regression introduced in
commit 18171bc774 ("Bluetooth: Host: Non-discardable event
buffer size is 255 for ext adv"). The default discardable Rx
buffer size was reduced causing increased fragmentation and
deadlock trying to get more free discardable Rx buffers to
generate HCI Extended and Periodic Advertising reports.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
This reverts commit e7489d8de7.
And fixes the deadlock by allowing only 1 thread to actualy clean up
the connection when the ref_count is 0.
Signed-off-by: Daniel Nejezchleb <dnejezchleb@hwg.cz>
Fixes issue #39989.
Save CCC data on pairing complete by replacing private addresses
for the just bonded device with its public address in CCC attributes'
CFG arrays. This is then followed by calls to bt_gatt_store_ccc
and bt_gatt_store_cf for the just bonded device.
Signed-off-by: Jim Benjamin Luther <jilu@oticon.com>
On some platforms, if there are multiple MODBUS interfaces,
receiving of RTU frames may fail. Replacing while loop with
just "if" fixes this problem.
Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
Fix race condition in setting up ISR callback and parameter
caused between ULL_HIGH and LLL context. As LLL IRQ is not
disabled the parameter and ISR callback would get out of
sync causing incorrect parameter supplied to callback and
hence leading to development assert in ull_scan_done().
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fix missing use of auxiliary context to generate done event
which caused leak in release of auxiliary context being not
release when reference count that should decrease to zero.
Regression in 'commit 665a8d2c6e ("Bluetooth: Controller:
Fix repeated per sync drift compensations").
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fix reset of is_aux_sched flag when closing the primary and
auxiliary PDU reception. Without this fix when scan window
is closed there would be duplicate auxiliary release message
generated causing memory corruption.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Add development assert to check the validity of auxiliary
context allocation. This is to ensure that primary PDU
reception does not have an auxiliary context allocated until
ULL has processed the node rx.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Add development assert to check the validity of auxiliary
context's parent. This is to ensure a released auxiliary
context is not reused without allocation.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
This patch is to fix an issue where the transceiver chip is
disabled before it has transmitted all data. This causes the
message to be corrupted because the last few bytes are missing.
The fix adds a check to make sure the transmission is completed
before disabling the transceiver.
Signed-off-by: Marius Scholtz <mariuss@ricelectronics.com>