When using target mode, we've found that some times the msg field can
be null through some of the code paths of the interrupt event handler.
Signed-off-by: Yuval Peress <peress@google.com>
Avoid k_sleep() never being called when video_write_reg_retry() and
video_read_reg_retry() have a number of retry set to zero (default).
The default number of retries being controlled by
CONFIG_VIDEO_I2C_RETRY_NUM.
Signed-off-by: Josuah Demangeon <me@josuah.net>
When using Zero Latency IRQs do not invoke ISR_DIRECT_PM and
do not return to reschedule in the kernel.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
The `owned-channels` property specifies which channels are assigned to
a given target. Additionally, the `source-channels` or `sink-channels`
property defines channels that can be used to forward an event outside
the DPPI domain, otherwise they can only be used within it.
Signed-off-by: Adam Kondraciuk <adam.kondraciuk@nordicsemi.no>
The async_user_callback could be triggered from
both the DMA transfer complete interrupt and
a k_work queue timeout. Since the timeout runs
outside of an ISR context, it could be interrupted
by the DMA ISR. This might leads to a race condition
where both paths access and modify shared
DMA buffer state (offset and length) simultaneously,
causing data corruption or out-of-sequence processing.
Introduces proper synchronization to prevent concurrent
access to shared DMA buffer variables,
ensuring consistent and reliable data handling.
Signed-off-by: Fabrice DJIATSA <fabrice.djiatsa-ext@st.com>
Add clear, step-by-step guide for generating test certificates using
FreeRADIUS scripts, including file renaming and usage notes.
Signed-off-by: Chaitanya Tata <Chaitanya.Tata@nordicsemi.no>
Fixes the JEDEC-ID value of the W25Q32JVWJ on-chip flash of RT1024.
It was incorrectly set to the value for the different IS25WP064 chip.
Signed-off-by: Andrej Butok <andrey.butok@nxp.com>
Allow network shell DNS module to verify that the DNS SD
record is a valid one. Currently this is not exposed to
applications.
Signed-off-by: Jukka Rissanen <jukka.rissanen@nordicsemi.no>
Fixes building an lvgl sample with CONFIG_CPU_LOAD enabled.
cpu_load_get function requires 1 argument.
Signed-off-by: Matthias Alleman <matthias.alleman@basalte.be>
In high throughput tests it's fairly easy to overflow the current 32-bit
byte counters in net statistics (it's just over 4 GB of data).
Therefore, make the byte counters 64-bit to prevent overflows.
Rearrange some fields to avoid padding.
Signed-off-by: Robert Lubos <robert.lubos@nordicsemi.no>
net_stats_t type is an unsigned type, therefore %u should be used
instead of %d when printing values of this type, otherwise negative
values will be printer if INT32_MAX is exceeded.
Signed-off-by: Robert Lubos <robert.lubos@nordicsemi.no>
Microchip is adding more non-MEC devices to Zephyr such as
SAM and PIC32. Each device family will have its own subfolder.
We moved the existing MEC DTSI files into a new mec subfolder.
We also updated the existing MEC boards include paths.
Signed-off-by: Scott Worley <scott.worley@microchip.com>
Updated driver based on changes done in SDK 25.06.00-pvw2.
Update hal_nxp to include BLE LL and IEEE 802.15.4 PHY NBU
combo firmware for MCXW72 boards.
Signed-off-by: Cristian Bulacu <cristian.bulacu@nxp.com>
Updated mcxw_get_time function to output its result in nanosecond
resolution and updated code accordingly.
Signed-off-by: Cristian Bulacu <cristian.bulacu@nxp.com>
Restore main stack size to the default value since fake entropy
implementation from mbedtls is replaced by STM32 entropy driver.
Signed-off-by: Ali Hozhabri <ali.hozhabri@st.com>
Call entropy APIs to use TRNG peripheral on STM32WB0x devices for BLE
purposes.
Enable RNG node on Nucleo-WB0x boards.
Remove RNG initialization as it's done in the entropy driver.
Signed-off-by: Ali Hozhabri <ali.hozhabri@st.com>
On Cortex-M33 the access to peripheral registers doesn't act as a data
synchronization barrier for memory accesses to normal memory. So before
triggering any TASKS for cache operations we need to make sure the core
doesn't have any pending memory transactions.
Signed-off-by: Karsten Koenig <karsten.koenig@nordicsemi.no>
When reception is restarted (STARTRX after ENDRX but no STOPRX) it is
possible that FRAMETIMEOUT countdown counter will not be started by
the first received byte if byte was already being transmitted when
STARTRX was called. If that is the only byte then it is expected that
timeout will be triggered but since FRAMETIMEOUT counter is not started
there is no FRAMETIMEOUT event which has short to STOPRX. This
situation will happen in case short buffers are used (< 5 bytes)
because then short ENDRX_STARTRX is not used then.
Signed-off-by: Krzysztof Chruściński <krzysztof.chruscinski@nordicsemi.no>
Converting absolute system ticks to RTC ticks is simple. It needs to be
multiplied by CYC_PER_TICK (which by default is 1). Complex algorithm
was used when driver was not tracking current 64 bit tick and function
was returning uint32_t.
Signed-off-by: Krzysztof Chruściński <krzysztof.chruscinski@nordicsemi.no>
[Description]
After DUT connects to AP through DPP,
enter 'wifi status' to check connection status.
Security shows UNKNOWN.
[Analysis]
1. DUT supplicant will add a dpp network after
receiving GAS response.
Assign ssid->key_mgmt as WPA_KEY_MGMT_DPP.
2. Call wpas_key_mgmt_to_zephyr() to convert
hostapd/supplicant security type to zephry
security type.
In this function, convert WPA_KEY_MGMT_DPP
to WIFI_SECURITY_TYPE_UNKNOWN.
[Fix]
1. Add code to convert WPA_KEY_MGMT_DPP
to WIFI_SECURITY_TYPE_DPP.
Signed-off-by: Qiankun Li <qiankun.li@nxp.com>
Specify the Arduino serial node for a Discovery kit with STM32H573II MCU.
Add supported features to board yaml file.
Signed-off-by: Pieter De Gendt <pieter.degendt@basalte.be>
When testing y2k rollover, the seconds value can easily be off by one
since there is no guarantee that the RTC will be exactly on the second
boundary.
Relax the check to allow for a one second difference.
Signed-off-by: Benjamin Cabé <benjamin@zephyrproject.org>
Ensure the alarm tests exercise rollover scenarios by setting RTC time
to a few seconds before midnight on a December 31st and alarm time to a
few seconds after midnight on the following day.
Signed-off-by: Benjamin Cabé <benjamin@zephyrproject.org>
Add information about nfct node status. For cpuapp status is irrelevant
because NFCT is by default assigned to cpuapp but for cpurad node needs
to have reserved status.
Signed-off-by: Krzysztof Chruściński <krzysztof.chruscinski@nordicsemi.no>
NFCT is by default assigned to application so DT node does
not need to be enabled or reserved in DT to have access to
NFCT registers. On cpurad NFCT must be reserved to enable
register access and then antenna pins can be configured as
gpios.
Signed-off-by: Krzysztof Chruściński <krzysztof.chruscinski@nordicsemi.no>
Use nordic,nrf-nfct-v2 compatible in the main nrf54h20 devicetree
description.
Signed-off-by: Krzysztof Chruściński <krzysztof.chruscinski@nordicsemi.no>
When both NRF_CLOCK_HAS_XO_TUNE and NRF_CLOCK_HAS_PLL evaluate to 0,
one break statement can end up not associated with any case and become
dead code. Refactor a bit the related switch to avoid such situation.
Signed-off-by: Andrzej Głąbek <andrzej.glabek@nordicsemi.no>
Add nRF specific test to check if it possible for multiple users
to enable XIP independently and also if XIP can be successfully
re-enabled (see fb1d0785ae).
Signed-off-by: Andrzej Głąbek <andrzej.glabek@nordicsemi.no>
Add reference counting in nrf_qspi_nor_xip_enable() so that XIP is
kept enabled as long as there is at least one user that needs it
(boot time enabling done with CONFIG_NORDIC_QSPI_NOR_XIP also counts).
Signed-off-by: Andrzej Głąbek <andrzej.glabek@nordicsemi.no>
On arrays DT_ENUM_HAS_VALUE() and DT_INST_ENUM_HAS_VALUE()
were only checking the first index, this changes it to check all indexes.
Signed-off-by: Fin Maaß <f.maass@vogl-electronic.com>