If ticks is K_TICKS_FOREVER the register autoreload isn't set.
So, on the next call to the z_clock_set_timeout function
the wait for the flag ARROK will be infinite.
Signed-off-by: Julien D'Ascenzio <julien.dascenzio@paratronic.fr>
Used for permission validation when accessing the associated file
descriptors from user mode.
There often get defined in implementation code, expand the search
to look in drivers/ and subsys/net/.
Signed-off-by: Andrew Boie <andrew.p.boie@intel.com>
This is a follow-up to commit cf7dd4981f.
When disabling RX, it is necessary to clear the RXSTARTED event after
the ENDRX_STARTRX shortcut is deactivated, as the event might already
have been generated at this point. If the event is not cleared and
the disabling of RX is done from the user handler called in the context
of the ENDRX interrupt, a spurious UART_RX_BUF_REQUEST event will be
generated (although RX is already disabled) for which a corresponding
call to uart_rx_buf_rsp() would fail, as the second buffer is already
set. Depending on the application implementation, this can result in
other unexpected problems.
Signed-off-by: Andrzej Głąbek <andrzej.glabek@nordicsemi.no>
We don't need to reset backup domain to set LSE clock source.
It's dangerous to reset backup domain, it removes:
- RTC configuration
- backup registers
- RCC Backup domain control register
Signed-off-by: Julien D'Ascenzio <julien.dascenzio@paratronic.fr>
Having a completion wait function release a lock internally only when
the operation fails is confusing. Remove that feature, and make the
lock and unlock operations explicit and paired.
This makes it much more clear how to properly handle transactions that
require multiple calls to the HAL.
Signed-off-by: Peter Bigot <peter.bigot@nordicsemi.no>
The stack buffer used to pad small reads must still be aligned to a
word address as the underlying driver uses DMA transfers with that
requirement. Don't assume the compiler will naturally align it.
Signed-off-by: Peter Bigot <peter.bigot@nordicsemi.no>
The check for small transfers inadvertently allowed a transfer of zero
bytes, which should be an error (invalid parameter).
Signed-off-by: Peter Bigot <peter.bigot@nordicsemi.no>
The consequent and alternate expressions for COND_CODE_1 must be
enclosed in parentheses, like this:
COND_CODE_1(PREDICATE, (consequent), (alternate))
The parens are missing in exactly one place in the tree. Fix it.
Reported-by: Peter Bigot <peter.bigot@nordicsemi.no>
Signed-off-by: Martí Bolívar <marti.bolivar@nordicsemi.no>
Activation of the LPTIMER is valid for SLEEP MODE only
The choice of the lptim clock source is STM32_LPTIM_CLOCK
set the LSE in first position to have as default value
Signed-off-by: Francois Ramu <francois.ramu@st.com>
based on PR#25412
Some kernel tests use `CONFIG_TICKLESS_KERNEL=n` with
`CONFIG_SYS_CLOCK_TICKS_PER_SEC=1` to detect when a test runs longer
than 1 second. These tests break if a tick is announced every time a
timeout occurs. Only announce if the measured duration since the last
tick is at least the duration of a tick.
Signed-off-by: Francois Ramu <francois.ramu@st.com>
set the min and max values of the given ticks from 0
to LPTIM_TIMEBASE which is the full register value
In case the timeout is FOREVER, then lptimer is stopped
Signed-off-by: Francois Ramu <francois.ramu@st.com>
The current value of the counter must not be added to the accumulator.
It will be added when calling z_timer_cycle_get_32.
Signed-off-by: Julien D'Ascenzio <julien.dascenzio@paratronic.fr>
When the tickless kernel isn't used, we don't want to wait for ARROK.
This wait can be endless.
Signed-off-by: Julien D'Ascenzio <julien.dascenzio@paratronic.fr>
The power configuration is dependent on which SPI is physically used.
In order to allow DT_INST_FOREACH_STATUS_OKAY() to iterate through
instances without the assumption that index 0 corresponds to SPI0
(which would be incorrect in the case when only SPI1 is enabled),
we need to check the base address to identify which SPI is being dealt
with.
Fixes#25673
Signed-off-by: Vincent Wan <vincent.wan@linaro.org>
The implementation of offload_getaddrinfo in this driver failed
when the node it was called with was an IP address. This condition
was never detected, and as a consequence a DNS query was done on
the IP address instead of returning it directly.
Also, the port was set first after running the DNS query.
As a consequence, if the IP address would have been returned directly,
this would have been done without a port been set.
Both errors are fixed in this patch.
Signed-off-by: Hans Wilmers <hans@wilmers.no>
Prevent usage of system work queue before it is ready by delaying
initialization of temperature device. Work queue is not used until
application stage.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
There does not seem to be a simple way to express the fact that UART1
can be initialized later at the POST_KERNEL level. The existing code
is wrong in the sense that it always initializes DT instance 1 later,
instead of doing it for UART1 (which may not be instance 1).
In addition, UART instances on other platforms are
also initialized at the PRE_KERNEL_1 level regardless of the instance
index, so let's do the same on this platform for consistency.
Signed-off-by: Vincent Wan <vincent.wan@linaro.org>
The power configuration is dependent on which UART is physically used.
In order to allow DT_INST_FOREACH_STATUS_OKAY() to iterate through
instances without the assumption that index 0 corresponds to UART0
(which would be incorrect in the case when only UART1 is enabled),
we need to check the base address to identify which UART is being dealt
with.
Signed-off-by: Vincent Wan <vincent.wan@linaro.org>
This reimplements z_timer_cycle_get_32() so it works
when IRQs are locked and solves the hung
k_busy_wait() problem.
Fixes#23622.
Signed-off-by: Jakub Cebulski <jcebulski@internships.antmicro.com>
Signed-off-by: Tomasz Gorochowik <tgorochowik@antmicro.com>
Signed-off-by: Mateusz Holenko <mholenko@antmicro.com>
Co-authored-by: Tomasz Gorochowik <tgorochowik@antmicro.com>
Updating the eswifi driver to provide port information (along with
IP / net context) whenever an async message is received. This is
needed to fully populate the "remote" info in "net_context"
required whenever net_context_send is called.
Also adding code to populate "remote" info in "net_context"..
Tested with STM32 disco IOT kit. Fixes#25621
Signed-off-by: Bilal Wasim <bilalwasim676@gmail.com>
When the loop that tries to obtain the lock in poll_out() finishes
because of hitting the max number of trials (what normally should
never happen), force the lock to be taken instead of just giving up
with sending the data. The latter approach that was in use so far
could not deal with a situation when some thread was aborted while
keeping the lock. Other threads would then have no chance to send
anything with poll_out() until it was called from an ISR.
Signed-off-by: Andrzej Głąbek <andrzej.glabek@nordicsemi.no>
Correct dependency of the TEMP_NRF5 Kconfig option so that it can be
enabled only on nRF SoCs that feature the TEMP peripheral.
Signed-off-by: Andrzej Głąbek <andrzej.glabek@nordicsemi.no>
Some Kconfig defined devices may be defined using dt_chosen_label
function. Since there is no way to ensure a device enabled in dts
is also defined in Kconfig, it may happen that instance is not
actually defined.
In this case device_get_binding might return 0, leading to undefined
behavior in the function that calls it.
When not already done, systematically check return of function
device_get_binding on devices defined through dt_chosen_label macro.
Trigger ASSERT when required and return error when possible.
Fixes#20068
Signed-off-by: Erwan Gouriou <erwan.gouriou@linaro.org>
Nordic driver must allow read from control OUT endpoint by
itself. For data stage transactions with length > MPS (64Bytes)
this must be performed for each 64B + Residue data packet.
Residue - data packet with len < 64B.
The exact length of data transfer is known from wLength field
form setup packet in setup stage. Until now driver was incorrectly
initializing the length of the data stage and at some point will
not allow for next data stage.
This commit addresses the issue #23980.
Signed-off-by: Emil Obalski <emil.obalski@nordicsemi.no>
The weak implementation returns 0 for all operations without doing
anything, which incorrectly suggests that an operation like
device_get_power_state() returned an accurate description of the
system clock power state. Return -ENOTSUP instead.
Signed-off-by: Peter Bigot <peter.bigot@nordicsemi.no>
If timeout is being overwrite exactly when previous one is expiring
then hardware event was cleared correctly but interrupt was already
triggered. Interrupt routine was assuming that compare event is set
and proceed with that assumption. However, in that corner case when
compare event was overwritten and event was cleared, that was not the
case.
As the outcome, timeout could be triggered prematurely. Fixed by
clearing pending interrupt after handling previous compare value.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
mcuboot and possibly other tools read single byte values to determine
the state of objects. Rather than fail to do the read of values too
short for this peripheral detect the situation and read into a stack
buffer that meets the length criteria, and on success copy the data
into the provided buffer.
Signed-off-by: Peter Bigot <peter.bigot@nordicsemi.no>
* still need to clear IP bit in timer irq handler
* last_time should be aligned to ticks, old code will miss some
cycles which are about (curret_time - last_time) % CYC_PER_TICK
* in timeout set, shorten the delay needed when tick is 0, this
will improve the response of timer irq
Signed-off-by: Wayne Ren <wei.ren@synopsys.com>
the pulse triggered timer irq doesn't work for all targets. In
iotdk, we found the clear of IP bit will clear int request
when elapsed called in thread context. So come back to level
triggered way which is supported in all targets, and use the sw
triggered irq to remember the irq request which may be cleared
in non timer int handler.
Signed-off-by: Wayne Ren <wei.ren@synopsys.com>
* rename overflow_cyc to overflow_cycles for better understanding
* use MIN macro to replace if .. else ..
* typo fix in comments
Signed-off-by: Wayne Ren <wei.ren@synopsys.com>
Allow configuring the clock prescaler divider for the NXP Kinetis
FlexTimer. Setting the prescaler to a lower value allows for much
higher resolution/accuracy for the generated PWM waveforms.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
User can now add extra Ethernet TAP parameters when starting QEMU.
This is useful if we want to set for example the MAC address
of the network interface.
Signed-off-by: Jukka Rissanen <jukka.rissanen@linux.intel.com>
When PCIe is enabled for UART, the port address is probed during
initialization and is written back into the device config struct.
However, the device config struct is supposed to be const and
read only. This results in page faults when MMU is enabled as
the struct cannot be written into. So fix this by storing port
address in device data struct if a particular UART instance is
of PCIE.
Signed-off-by: Daniel Leung <daniel.leung@intel.com>
The init function returns successful even if the first
configuration function call fails. This may leave
a non-usable UART to be discoverable with
device_get_binding() which will definitely result
in lots of head scratching. So change the init function
to return properly.
Signed-off-by: Daniel Leung <daniel.leung@intel.com>
This adds the calls to read_timer_{start,end}_of_tick_handler()
to mark the start and end of ISR which will be used to display
the time spent in ISR with benchmarking tests.
Signed-off-by: Daniel Leung <daniel.leung@intel.com>
IRQ_CONNECT() can only be called at one location to connect the irq for
CPE0. This commit modifies the driver to call into the HwiP layer in TI
HAL so that TI's RF driver can do the same when connecting the irq.
Fixes#25216
Signed-off-by: Vincent Wan <vincent.wan@linaro.org>