Calling for can_stop() method was not emptying FIFOs
and tx_msgq.
Resetting TX FIFO to empty it.
Emptying tx_msgq with "ENETDOWN" return code.
Fixes#50546
Signed-off-by: Aymeric Aillet <aymeric.aillet@iot.bzh>
Driver was based on can_sam. SAMC21 has only 1 interrupt for one
can "output", so can interrupt has to executes two lines of
interrupts.
CAN is configured to use OSC48M clock via GLCK7. GLCK7 is set
by divider configured from dts.
Signed-off-by: Kamil Serwus <kserwus@gmail.com>
Add Kconfig guards for CONFIG_CAN_MAX_STD_ID_FILTER and
CONFIG_CAN_MAX_EXT_ID_FILTER as they only apply to the STM32 bxCAN driver.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Remove the STM32H7 specific Kconfig overrides for setting the maximum
number of standard and extended CAN RX filters as they are unused.
The number of available standard and extended filter elements for Bosch
M_CAN can be configured via the devicetree.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Move definitions of the STM32 FDCAN specific registers to the front-end
driver implementation and implement remapping of these registers to/from
the standard Bosch M_CAN registers.
Some of the STM32 FDCAN register bit fields are limited in size compared to
the Bosch M_CAN specification. This is due to hardware limitations on the
number of elements in the various sections of the Message RAM. Add build
assertions to ensure the number of elements specified do not exceed the
hardware limitations instead of using custom definitions for these fields.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Move definition of the NXP LPC MCAN specific Message RAM Base Address
register (MRBA) to the front-end driver implementation.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Some Bosch M_CAN IP core implementations use a fixed Message RAM
configuration, other use a fixed memory area and relative addressing,
others again have custom registers for configuring the Message RAM.
Move the responsibility for configuring the various Bosch M_CAN Message RAM
addresses to the front-end drivers. This removes some of the front-end
specific code from the backend. Provide a helper function for configuring
the most common variations.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Expose the can_mcan_read_reg()/can_mcan_write_reg() along with all the
Bosch M_CAN register definitions for use in Bosch M_CAN driver front-ends.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Let the Bosch M_CAN front-end drivers supply their own register read/write
functions.
This is preparation for handling non-standard Bosch M_CAN register layouts
directly in the front-end and for accessing Bosch M_CAN IP cores over
peripheral busses.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Use sys_read32()/sys_write32() instead of volatile struct for register
access. Be consistent in using unsigned constants in register
comparisons. Use locking around register read-modify-write operations.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Regenerate/rewrite the Bosch M_CAN register field definitions using the
GENMASK() and BIT() macros.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Use the FIELD_PREP() and FIELD_GET() macros instead of manual bitshifts and
masking. Be consistent in the use of register field definition macros.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Rename the local "const struct can_mcan_config *" variables from "cfg" to
"config" to be consistent with Zephyr conventions.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Get rid of the can_mcan_configure_timing() helper function as it provides
no benefit to just having the implementation split in can_mcan_set_timing()
and can_mcan_set_timing_data().
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Move the driver initialization function to the bottom of the file to be
consistent with Zephyr conventions.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Pass a pointer to the struct device for internal driver functions instead
of passing around a pointer to the register struct.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
This patch introduces support for NXP S32 CANEXCEL (CANXL) peripheral.
CAN protocol supporting:
- CAN classic
- CAN FD
Remote transmission request is not supported as this feature is not
available on NXP S32 CANXL HAL.
Signed-off-by: Cong Nguyen Huu <cong.nguyenhuu@nxp.com>
The MCUX platform always uses pinctrl, there's no need to keep extra
macrology around pinctrl. Also updated driver's Kconfig options to
`select PINCTRL` (note that some already did).
Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
Remove all init functions that do nothing, and provide a `NULL` to
*DEVICE*DEFINE* macros.
Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
Rename the nxp,kinetis-flexcan devicetree compatible to nxp,flexcan as it
is not specific to the NXP Kinetis series.
This is preparation for adding a nxp,flexcan-fd binding.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Unify the drivers/*/Kconfig menuconfig title strings to the format
"<class> [(acronym)] [bus] drivers".
Including both the full name of the driver class and an acronym makes
menuconfig more user friendly as some of the acronyms are less well-known
than others. It also improves Kconfig search, both via menuconfig and via
the generated Kconfig documentation.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Add documentation for the update_sampling_pnt() function and rename a few
internal variables to improve readability.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Respect the range limits of phase_seg1 when attempting to distribute ts1
between prop_seg and phase_seg1.
Even distribution may not be possible if the allowed ranges of prop_seg and
phase_seg1 are not equal.
Fixes: #55919
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Check the requested CAN timing parameters against the min/max values
supported by the driver and return an error if they are out of range.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Add support for setting the Synchronization Jump Width (SJW) for both the
classic/arbitration phase and the CAN-FD data phase.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Move the can_sja1000.h header file to the public
include/zephyr/drivers/can/ include path. This allows writing out-of-tree
SJA1000 based driver front-ends.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
Rename the can_utils_filter_match() utility function to
can_frame_matches_filter(), move it to the public
include/zephyr/drivers/can.h header file, and add a missing mismatch for
standard (11-bit) ID frames passing extended (29-bit) filters.
This allows using the utility function in out-of-tree CAN drivers.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
This commit aims at updating the drivers stop function to better
follow the CAN header file which specifiec that stopping the CAN
controller should "abort any pending CAN frame transmissions".
Signed-off-by: Benjamin Björnsson <benjamin.bjornsson@gmail.com>
Remove the CAN_HAS_CANFD Kconfig helper symbol in order to allow enabling
CAN-FD support in the API regardless of driver support.
Change default to CAN-FD support being disabled and have samples and tests
that require CAN-FD support turn it on. This aligns the default
configuration across CAN controller drivers regardless of their
capabilities.
The rationale behind this is that we are starting to see MCUs with multiple
CAN controllers, some CAN-FD compatible, some not (e.g. NXP i.MX RT1060 and
FPGAs). Automatically enabling CAN-FD support based on the presence of a
CAN-FD capable CAN controller leads to different application default
settings based on the CAN controller(s) in use.
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>