zephyr/samples/sensor/mhz19b
Keith Packard 0b90fd5adf samples, tests, boards: Switch main return type from void to int
As both C and C++ standards require applications running under an OS to
return 'int', adapt that for Zephyr to align with those standard. This also
eliminates errors when building with clang when not using -ffreestanding,
and reduces the need for compiler flags to silence warnings for both clang
and gcc.

Most of these changes were automated using coccinelle with the following
script:

@@
@@
- void
+ int
main(...) {
	...
-	return;
+	return 0;
	...
}

Approximately 40 files had to be edited by hand as coccinelle was unable to
fix them.

Signed-off-by: Keith Packard <keithp@keithp.com>
2023-04-14 07:49:41 +09:00
..
boards samples: sensors: Remove label property from devicetree overlays 2022-07-19 08:23:35 -05:00
src samples, tests, boards: Switch main return type from void to int 2023-04-14 07:49:41 +09:00
CMakeLists.txt samples: sensor: Add sample for MH-Z19B 2021-12-20 18:47:47 +01:00
prj.conf sensors: Remove unnecessary Kconfig setting of sensors 2022-07-25 15:18:56 +02:00
README.rst samples: sensor: Add sample for MH-Z19B 2021-12-20 18:47:47 +01:00
sample.yaml samples: sensor: Add sample for MH-Z19B 2021-12-20 18:47:47 +01:00

.. _mhz19b-sample:

MH-Z19B: CO2 Sensor Sample
##########################

Description
***********

This sample application demonstrate the configurations of the MH-Z19B CO2
sensor, then periodically reads CO2 data from the sensor. The driver
currently only support uart interrupt APIs.

Requirements
************

The baudrate of the UART must be configured to 9600, and must support
interrupt driven API.

Building and Running
********************

To build the application, a board with UART interface
has to be chosen, or a custom devicetree overlay has to be provided.
Here Nucleo G0B1RE board is used.
Then, connect the RX and TX from your Zephyr target board to the
MH-Z19B CO2 sensor and power the sensor according to the datasheet.

.. zephyr-app-commands::
   :zephyr-app: samples/sensor/mhz19b
   :board: nucleo_g0b1re
   :goals: build
   :compact:

Sample Output
=============

The application will perform runtime configuration of the sensor, then
read back the sensor configuration data. After that it will read the CO2
data every 2 seconds.

.. code-block:: console

   Winsen MH-Z19B CO2 sensor application
   Configuring sensor - OK
   Reading configurations from sensor:
   Sensor range is set to 5000ppm
   Sensor ABC is enabled
   sensor: co2 reading: 758
   sensor: co2 reading: 759
   sensor: co2 reading: 762