# Bosch BMI160 inertial measurement configuration options # Copyright (c) 2016 Intel Corporation # SPDX-License-Identifier: Apache-2.0 menuconfig BMI160 bool "Bosch BMI160 inertial measurement unit" depends on SPI help Enable Bosch BMI160 inertial measurement unit that provides acceleration and angular rate measurements. if BMI160 choice prompt "Trigger mode" default BMI160_TRIGGER_GLOBAL_THREAD help Specify the type of triggering to be used by the driver. config BMI160_TRIGGER_NONE bool "No trigger" config BMI160_TRIGGER_GLOBAL_THREAD bool "Use global thread" select BMI160_TRIGGER config BMI160_TRIGGER_OWN_THREAD bool "Use own thread" select BMI160_TRIGGER endchoice config BMI160_TRIGGER bool config BMI160_THREAD_PRIORITY int "Own thread priority" depends on BMI160_TRIGGER_OWN_THREAD default 10 help The priority of the thread used for handling interrupts. config BMI160_THREAD_STACK_SIZE int "Own thread stack size" depends on BMI160_TRIGGER_OWN_THREAD default 1024 help The thread stack size. choice prompt "Accelerometer power mode" default BMI160_ACCEL_PMU_RUNTIME config BMI160_ACCEL_PMU_RUNTIME bool "Set at runtime." config BMI160_ACCEL_PMU_SUSPEND bool "suspended/not used" config BMI160_ACCEL_PMU_NORMAL bool "normal" config BMI160_ACCEL_PMU_LOW_POWER bool "low power" endchoice choice prompt "Accelerometer range setting" depends on BMI160_ACCEL_PMU_RUNTIME || BMI160_ACCEL_PMU_NORMAL || BMI160_ACCEL_PMU_LOW_POWER default BMI160_ACCEL_RANGE_RUNTIME config BMI160_ACCEL_RANGE_RUNTIME bool "Set at runtime." config BMI160_ACCEL_RANGE_2G bool "2G" config BMI160_ACCEL_RANGE_4G bool "4G" config BMI160_ACCEL_RANGE_8G bool "8G" config BMI160_ACCEL_RANGE_16G bool "16G" endchoice choice prompt "Accelerometer sampling frequency." depends on BMI160_ACCEL_PMU_RUNTIME || BMI160_ACCEL_PMU_NORMAL || BMI160_ACCEL_PMU_LOW_POWER default BMI160_ACCEL_ODR_RUNTIME config BMI160_ACCEL_ODR_RUNTIME bool "Set at runtime." config BMI160_ACCEL_ODR_25_32 depends on BMI160_ACCEL_PMU_LOW_POWER bool "0.78 Hz" config BMI160_ACCEL_ODR_25_16 depends on BMI160_ACCEL_PMU_LOW_POWER bool "1.56 Hz" config BMI160_ACCEL_ODR_25_8 depends on BMI160_ACCEL_PMU_LOW_POWER bool "3.125 Hz" config BMI160_ACCEL_ODR_25_4 depends on BMI160_ACCEL_PMU_LOW_POWER bool "6.25 Hz" config BMI160_ACCEL_ODR_25_2 bool "12.5 Hz" config BMI160_ACCEL_ODR_25 bool "25 Hz" config BMI160_ACCEL_ODR_50 bool "50 Hz" config BMI160_ACCEL_ODR_100 bool "100 Hz" config BMI160_ACCEL_ODR_200 bool "200 Hz" config BMI160_ACCEL_ODR_400 bool "400 Hz" config BMI160_ACCEL_ODR_800 bool "800 Hz" config BMI160_ACCEL_ODR_1600 bool "1600 Hz" endchoice choice prompt "Gyroscope power mode" default BMI160_GYRO_PMU_RUNTIME config BMI160_GYRO_PMU_RUNTIME bool "Set at runtime." config BMI160_GYRO_PMU_SUSPEND bool "suspended/not used" config BMI160_GYRO_PMU_NORMAL bool "normal" config BMI160_GYRO_PMU_FAST_STARTUP bool "fast start-up" endchoice choice prompt "Gyroscope range setting." depends on BMI160_GYRO_PMU_RUNTIME || BMI160_GYRO_PMU_NORMAL || BMI160_GYRO_PMU_FAST_STARTUP default BMI160_GYRO_RANGE_RUNTIME config BMI160_GYRO_RANGE_RUNTIME bool "Set at runtime." config BMI160_GYRO_RANGE_2000DPS bool "2000 DPS" config BMI160_GYRO_RANGE_1000DPS bool "1000 DPS" config BMI160_GYRO_RANGE_500DPS bool "500 DPS" config BMI160_GYRO_RANGE_250DPS bool "250 DPS" config BMI160_GYRO_RANGE_125DPS bool "125 DPS" endchoice choice prompt "Gyroscope sampling frequency." depends on BMI160_GYRO_PMU_RUNTIME || BMI160_GYRO_PMU_NORMAL || BMI160_GYRO_PMU_FAST_STARTUP default BMI160_GYRO_ODR_RUNTIME config BMI160_GYRO_ODR_RUNTIME bool "Set at runtime." config BMI160_GYRO_ODR_25 bool "25 Hz" config BMI160_GYRO_ODR_50 bool "50 Hz" config BMI160_GYRO_ODR_100 bool "100 Hz" config BMI160_GYRO_ODR_200 bool "200 Hz" config BMI160_GYRO_ODR_400 bool "400 Hz" config BMI160_GYRO_ODR_800 bool "800 Hz" config BMI160_GYRO_ODR_1600 bool "1600 Hz" config BMI160_GYRO_ODR_3200 bool "3200 Hz" endchoice endif # BMI160