The vref has to be set to 3000mV.
It is the voltage to find on the stm32F3.
is fixed by the platform to be lower or equal to VDDA.
Signed-off-by: Francois Ramu <francois.ramu@st.com>
This reverts the commit 7d8a119213
because GCC is now configured to not emit ldp/stp Qn instructions for
consecutive 32-byte loads and stores, and the nested interrupt handling
failure due to the missing emulation of these instructions no longer
occurs.
For more details, refer to the GitHub issue #49491 and #49806.
Signed-off-by: Stephanos Ioannidis <root@stephanos.io>
GCC may generate ldp/stp instructions with the Advanced SIMD Qn
registers for consecutive 32-byte loads and stores.
This commit disables this GCC behaviour because saving and restoring
the Advanced SIMD context is very expensive, and it is preferable to
keep it turned off by not emitting these instructions for better
context switching performance.
Signed-off-by: Stephanos Ioannidis <root@stephanos.io>
On power on reset, after disable advanced power safe mode,
you need to wait a delay before write again in the device.
The missing wait produce random initialization failure.
See §4.4 of the datasheet "bst-bmi270-ds000.pdf"
Signed-off-by: William MARTIN <william.martin@power-lan.com>
SAM V71 Xplained Ultra failed to re-enumerate on the bus after device
detach-attach sequence. The device was recognized by the host, but it
was not responding to control transfers, i.e. it was not acknowledging
SETUP data. Make device acknowledge SETUP data by reconfiguring EP0
when necessary.
Signed-off-by: Tomasz Moń <tomasz.mon@nordicsemi.no>
Device physically detaches when the DETACH bit is set. Fix the
assignment to actually set the bit instead of clearing it.
Signed-off-by: Tomasz Moń <tomasz.mon@nordicsemi.no>
When calculating the offsets between primary advertising
PDU, auxiliary PDU, Periodic Advertising PDU, and BIS PDU,
the values used as anchor points for starting the periodic
interval for auxiliary, periodic and BIG events, should be
ensured to have the minimum auxiliary frame spacing T_MAFS
between the PDUs.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Use a local variable to assert check on auxiliary context's
release.
Add missing volatile qualifier to the parent field of the
auxiliary scan context.
Under race condition a released aux context can be allocated
for reception of chain PDU of a periodic sync role, hence
fix the assertion check to consider that the released
context can be allocated to other roles.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Update the whole section based on what was in boards/*/* for v3.1.0 and
main. Sort the lists and remove the empty sections.
Signed-off-by: Fabio Baltieri <fabiobaltieri@google.com>
Add few release notes from changes in sections that do not list an
explicit maintainer, taken from:
git log v3.1.0..main drivers/interrupt_controller
git log v3.1.0..main drivers/memc
git log v3.1.0..main drivers/power_domain
Signed-off-by: Fabio Baltieri <fabiobaltieri@google.com>
Increase the BIS PDU access address receive timeout, use the
+/- 2 us jitter for each subevent.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
This logic was added before but seems to be missed during the
twister refactoring.
Some tests can cause serial leftover logs buffered somewhere.
Such leftover can interfere with the next test case because the
serial log monitoring thread is started before a board is flashed.
And the monitoring thread can be fooled by such leftover logs and
make incorrect judgement of the test result.
A simple ser.flush() is not enough to eliminate such leftovers.
So add explicit readline() to drain such logs which ensures a clean
serial context for the case that follows.
An example from reel board captured with this patch:
leftover log of previous test: b'.287 seconds\r\n'
leftover log of previous test: b' - SKIP - [...test_coredump_backend]...
leftover log of previous test: b'\r\n'
leftover log of previous test: b'------ TESTSUITE SUMMARY END ------\r\n'
leftover log of previous test: b'\r\n'
leftover log of previous test: b'=====================================...
leftover log of previous test: b'RunID: 4e93757ad...53dcab9f0f5c6\r\n'
leftover log of previous test: b'PROJECT EXECUTION SUCCESSFUL\r\n
Signed-off-by: Ming Shao <ming.shao@intel.com>
Fix inifinite loop in ll_rx_get() when both ISO Broadcast
and ISO Receive features are enabled in a build. Missing
conditional compile prevented the ack_last index that
maintains a relation between number of packets complete and
the received data packets was unassigned.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
According to Bluetooth 5.3 Vol 4, Part E section 7.7.65.21 the
Controller should send an IQ report with Packet_Status set to 0xFF
and Sample_Count to 0x0, to inform Host that it is not able to
store IQ samples for all received Constant Tone Extensions and has
failed to sample at least once.
This commit adds handling of such situation for direction finding
in connectionless mode in lower link layer. It includes:
- lack of node_rx_iq_report to store IQ samples,
- lack of free node_rx to report received advertising data (generates
an advertising data report with indication "incomplete, no more to
come" and cancels reception of chained PDUs,
- cancellation of chained PDUs reception due to other scheduling
reasons.
In all of these situations CTE reception must be enabled and number of
received CTEs is smaller than requested by Host.
If there is not sufficient number of node_rx_iq_report nodes and
report was generated, the CTE will not be samples in a given
periodic advertising synchronization event. The CTE will be
sampled again in next event if there are node_rx_iq_report available.
End user applications may check periodic advertising sync event
counter when use of the reports to be sure about sync event
the received report is connected with.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
The img_mgmt_erase could return MGMT_ERR_EOK even when
img_mgmt_impl_erase_slot failed.
Fixes#50522
Signed-off-by: Dominik Ermel <dominik.ermel@nordicsemi.no>
Update documentation for STM32U5 and STM32L5 based boards:
- Zepĥyr SDK openocd can be used instead of openocd ST fork.
- All these boards use a STLinkV3 instead of V2.
- Update (or provide when missing) instructions for building and
flashing TFM applications.
Signed-off-by: Erwan Gouriou <erwan.gouriou@linaro.org>
If the thread that submits data over spi is interrupted by a higher
priority thread while pushing data to the tx fifo the hardware pushes
data to spi and frees up space in the fifo. In this case more than
8 Bytes are written to the tx fifo and bytes in the rx fifo get lost
before they are collected in the rx while loop.
To avoid this, the tx loop is exited after a maximum of 8 bytes and the
rx loop will run until it collected all bytes from the rx fifo.
Signed-off-by: Gerhard Jörges <joerges@metratec.com>
Fixes: #49116
During development of out-of-tree boards and applications it is not
uncommon to refactor / restructure code.
To allow developers more freedom, let's check that board's defconfig
still exists during a CMake re-run.
If the defconfig no longer exists, either because it's been moved or
deleted, then warn the user and set BOARD_DIR to NOTFOUND.
The NOTFOUND will request CMake to search for the new location in all
board roots. If the board has not been found, as example it's deleted,
then the existing error is printed later.
Signed-off-by: Torsten Rasmussen <Torsten.Rasmussen@nordicsemi.no>
Fixes commit 7a85ff7683 ("add sparse support")
The sparse build needs (at least) two things:
1. sparse to be in the PATH
2. the environment variable REAL_CC to be defined and to match the
value expected by CMake
Fix error messages when either condition is wrong.
- New error message when 1. is not satisfied:
```
CMake Error at zephyr/cmake/compiler/gcc/target.cmake:12 (find_program):
Could not find CMAKE_C_COMPILER using the following names: cgcc
```
- Previous error "message" when 1. is not satisfied:
```
CMake Error at zephyr/cmake/compiler/gcc/target.cmake:17 (message):
C compiler
ZSDK/xtensa-intel_s1000_zephyr-elf/bin/xtensa-intel_s1000_zephyr-elf-gcc
not found - Please check your toolchain installation
```
Note the "not found" cross-compiler actually exists!
- New error message when 2. is not satisfied:
```
Kconfig header saved to 'ws/build-tgl/zephyr/include/generated/autoconf.h'
-- Found sparse: /home/user/sparse/cgcc
CMake Error at ws/zephyr/cmake/compiler/gcc/target.cmake:25 (message):
The only way to override its 'cc' default when cross-compiling with
sparse is unfortunately an environment variable. So you _must_ set
REAL_CC at both configuration time and build time to:
$ZSDK/xtensa-intel_s1000_zephyr-elf/bin/xtensa-intel_s1000_zephyr-elf-gcc
```
- Previous error "message" when 2. is not satisfied:
```
modules/hal/xtensa/include/xtensa/config/core.h:54:10:
error:unable to open 'core-isa.h'`
```
Also: stop using the same name REAL_CC for both the internal CMake
variable and the external sparse parameter; they're two different
things so name them differently. Environment variable messes are
complicated enough.
Signed-off-by: Marc Herbert <marc.herbert@intel.com>
This Commit makes the adc configuration correct
for using the adc with 12b conversion on the stm32wl.
TriggerSource must be set to SW.
The ADC clock must be disabled by clock gating during CPU1 sleep/stop.
Signed-off-by: Francois Ramu <francois.ramu@st.com>
1. To explicitly set the MSG_START flag on the first message.
2. Remove redundant declare.
3. Using data->msgs->flags is the correct address instead of
msgs->flags.
Signed-off-by: Tim Lin <tim2.lin@ite.corp-partner.google.com>
Add a couple of minor fixups to the CAN related release notes for Zephyr
v3.2.0 (fixed typo and removed duplicate entry).
Signed-off-by: Henrik Brix Andersen <hebad@vestas.com>
The GCC/GCOV version over 12 has slight format change of the gcno
and gcda. Make some adaption in the gcov dump function to fix the
code coverage report.
Mainly two places change:
1. Added the checksum in the struct gcov_info. This fix the crash
in qemu_x86, and mps2_an385 when run with --coverage.
2. Adjust the GCOV_TAG_FUNCTION_LENGTH accroding to gcov-io.h. It's
length unit is caculated by bytes now.
Fixes#50255.
Fixes#50257.
Signed-off-by: Enjia Mai <enjia.mai@intel.com>
This patch fixes a couple of syntax issues that lead to incorrectly
rendered content:
- Bad list indentation
- Missing blank line between list item and sub-item.
Also made 'label' a literal.
Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
Fix incorrect use of stream handle instead of connection
handle to enqueue Tx ISO Data, and use stream index to get
stream instance.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Twister detects FLASH overflow and skips tests that trigger that
condition by default, but sometimes images are just on the flash size
limit and then overflows at a later stage when imgtool adds a trailer,
which gets detected as a build fail and fails the run.
This detects the imgtool flash overflow together with the normal build
ones, causing the build to be skipped on imgtool flash overflow as well.
Signed-off-by: Fabio Baltieri <fabiobaltieri@google.com>
More GigaDevice support added, include drivers, boards, etc.
Also, some known issue has been fixed.
Signed-off-by: HaiLong Yang <hailong.yang@brainco.cn>
When the node is part of only one subnet, it starts Network ID
advertisements with infinite timeout. It is not an issue when using
legacy advertising and extended advertising with shared set for local
messages and GATT because any message will stop advertisements. However,
when a separate adv set is used for GATT advertisements,
`struct bt_le_ext_adv_cb.start` callback won't be called, but the
implementation relies on that callback to switch to a next subnet.
Calling `bt_mesh_adv_gatt_update()` stop GATT advertisement so that the
implementation can switch to the next subnet.
Signed-off-by: Pavel Vasilyev <pavel.vasilyev@nordicsemi.no>
Reduce advertising duration to `max_timeout` when advertising node
identity for multiple subnets. This will let the node to interleave
subnets for NODE_ID_TIMEOUT.
Signed-off-by: Pavel Vasilyev <pavel.vasilyev@nordicsemi.no>
`struct bt_le_ext_adv_start_param.timeout` resolution is in 10ms. When
duration is less than 10ms, division will be evaluated to zero, which
will result in indefinite timeout. Set timeout to 10ms to avoid
indefinite timeout. The advertisement will end earlier anyway after the
event is finished.
Signed-off-by: Pavel Vasilyev <pavel.vasilyev@nordicsemi.no>
This adds bits about PECI drivers:
* Devicetree binding changes for the ITE it8xxx2 driver.
* New driver for Nuvoton NPCX.
Signed-off-by: Daniel Leung <daniel.leung@intel.com>