Commit graph

5 commits

Author SHA1 Message Date
Andrzej Głąbek
20202902f2 dts_fixups: Use DT_ prefix in all defined labels not related to Kconfig
These changes were obtained by running a script  created by
Ulf Magnusson <Ulf.Magnusson@nordicsemi.no> for the following
specification:

1. Read the contents of all dts_fixup.h files in Zephyr
2. Check the left-hand side of the #define macros (i.e. the X in
   #define X Y)
3. Check if that name is also the name of a Kconfig option
   3.a If it is, then do nothing
   3.b If it is not, then replace CONFIG_ with DT_ or add DT_ if it
       has neither of these two prefixes
4. Replace the use of the changed #define in the code itself
   (.c, .h, .ld)

Additionally, some tweaks had to be added to this script to catch some
of the macros used in the code in a parameterized form, e.g.:
- CONFIG_GPIO_STM32_GPIO##__SUFFIX##_BASE_ADDRESS
- CONFIG_UART_##idx##_TX_PIN
- I2C_SBCON_##_num##_BASE_ADDR
and to prevent adding DT_ prefix to the following symbols:
- FLASH_START
- FLASH_SIZE
- SRAM_START
- SRAM_SIZE
- _ROM_ADDR
- _ROM_SIZE
- _RAM_ADDR
- _RAM_SIZE
which are surprisingly also defined in some dts_fixup.h files.

Finally, some manual corrections had to be done as well:
- name##_IRQ -> DT_##name##_IRQ in uart_stm32.c

Signed-off-by: Andrzej Głąbek <andrzej.glabek@nordicsemi.no>
2018-11-13 10:44:42 -06:00
Punit Vara
e5620a2b87 drivers: sensor: Migrate to new logger
Move all sensor drivers and samples to new logging system.

Signed-off-by: Punit Vara <punit.vara@intel.com>
2018-10-16 08:49:53 -04:00
Aapo Vienamo
fbd3c2f4e2 sensors: ccs811: Deassert the reset pin with GPIO
The driver releases the sensor from reset in case the reset pin is
driven by a GPIO.

Signed-off-by: Aapo Vienamo <aapo.vienamo@iki.fi>
2018-04-09 17:09:06 -05:00
Aapo Vienamo
0a6f8c1aa2 drivers: sensor: ccs811: Fix value conversion
The arithmetic performed on the CO2 and VOC measurements is pointless as
the units of the sensor already match those of the API, furthermore the
multiplication will overflow the u32_t with CO2 or VOC readings greater
than 4294 ppm or ppb. This CO2 concentration is achievable by breathing
at the sensor.

Signed-off-by: Aapo Vienamo <aapo.vienamo@iki.fi>
2018-03-05 13:23:38 -06:00
Manivannan Sadhasivam
9e88120fdf drivers: sensor: Add support for CCS811 Digital Gas Sensor
Add support for AMS CCS811 Digital Gas Sensor for monitoring
indoor air quality. This sensor reports the following parameters:

1. Co2 concentration
2. VOC concentration
3. Sensor voltage
4. Sensor current

This driver only supports polling mode as of now.

Signed-off-by: Manivannan Sadhasivam <manivannan.sadhasivam@linaro.org>
2018-02-06 11:16:26 -05:00