Bluetooth: Mesh: Move RPR models Kconfig options
Move RPR models Kconfig options under the models menu. Signed-off-by: Pavel Vasilyev <pavel.vasilyev@nordicsemi.no>
This commit is contained in:
parent
c2299e2120
commit
f89effbe75
1 changed files with 48 additions and 47 deletions
|
@ -1049,6 +1049,54 @@ config BT_MESH_DFD_SRV_OOB_UPLOAD
|
|||
|
||||
endif
|
||||
|
||||
config BT_MESH_RPR_SRV
|
||||
bool "Support for Remote Provisioning Server model"
|
||||
help
|
||||
The Remote Provisioning Server is the proxy for a provisioning
|
||||
process, allowing provisioners to tunnel their provisioning
|
||||
messages through the mesh to the Remote Provisioning Server, which
|
||||
communicates directly with the unprovisioned node.
|
||||
|
||||
config BT_MESH_RPR_CLI
|
||||
bool "Support for Remote Provisioning Client model"
|
||||
depends on BT_MESH_PROVISIONER
|
||||
help
|
||||
The Remote Provisioning Client is instantiated on the provisioner
|
||||
node, and allows provisioning of new devices through the mesh network
|
||||
by tunnelling provisioning messages to a Remote Provisioning Server.
|
||||
|
||||
menu "Remote Provisioning configuration"
|
||||
visible if BT_MESH_RPR_SRV || BT_MESH_RPR_CLI
|
||||
|
||||
config BT_MESH_RPR_AD_TYPES_MAX
|
||||
int "Max AD types in extended scanning"
|
||||
default 1
|
||||
range 1 16
|
||||
help
|
||||
During extended scanning, the Remote Provisioning Server can include
|
||||
a set of AD types in the scan reports, collected from the
|
||||
unprovisioned device's advertisement data. This option controls
|
||||
the highest number of AD types a single server can scan for, and a
|
||||
Client can request.
|
||||
|
||||
config BT_MESH_RPR_SRV_SCANNED_ITEMS_MAX
|
||||
int "Max scannable unprovisioned devices for Remote Provisioning Server"
|
||||
default 4
|
||||
range 4 255
|
||||
help
|
||||
Max number of unique unprovisioned devices a single Remote
|
||||
Provisioning Server can hold.
|
||||
|
||||
config BT_MESH_RPR_SRV_AD_DATA_MAX
|
||||
int "Max additional advertisement data to report"
|
||||
default 31
|
||||
range 3 255
|
||||
help
|
||||
Buffer size for the additional advertisement data reported during
|
||||
extended scanning.
|
||||
|
||||
endmenu # Remote Provisioning configuration
|
||||
|
||||
endmenu # Models
|
||||
|
||||
menu "Proxy"
|
||||
|
@ -1431,53 +1479,6 @@ config BT_MESH_FRIEND_ADV_LATENCY
|
|||
|
||||
endif # BT_MESH_FRIEND
|
||||
|
||||
config BT_MESH_RPR_SRV
|
||||
bool "Support for Remote Provisioning Server model"
|
||||
help
|
||||
The Remote Provisioning Server is the proxy for a provisioning
|
||||
process, allowing provisioners to tunnel their provisioning
|
||||
messages through the mesh to the Remote Provisioning Server, which
|
||||
communicates directly with the unprovisioned node.
|
||||
|
||||
config BT_MESH_RPR_CLI
|
||||
bool "Support for Remote Provisioning Client model"
|
||||
depends on BT_MESH_PROVISIONER
|
||||
help
|
||||
The Remote Provisioning Client is instantiated on the provisioner
|
||||
node, and allows provisioning of new devices through the mesh network
|
||||
by tunnelling provisioning messages to a Remote Provisioning Server.
|
||||
|
||||
menu "Remote Provisioning configuration"
|
||||
visible if BT_MESH_RPR_SRV || BT_MESH_RPR_CLI
|
||||
|
||||
config BT_MESH_RPR_AD_TYPES_MAX
|
||||
int "Max AD types in extended scanning"
|
||||
default 1
|
||||
range 1 16
|
||||
help
|
||||
During extended scanning, the Remote Provisioning Server can include
|
||||
a set of AD types in the scan reports, collected from the
|
||||
unprovisioned device's advertisement data. This option controls
|
||||
the highest number of AD types a single server can scan for, and a
|
||||
Client can request.
|
||||
|
||||
config BT_MESH_RPR_SRV_SCANNED_ITEMS_MAX
|
||||
int "Max scannable unprovisioned devices for Remote Provisioning Server"
|
||||
default 4
|
||||
range 4 255
|
||||
help
|
||||
Max number of unique unprovisioned devices a single Remote
|
||||
Provisioning Server can hold.
|
||||
|
||||
config BT_MESH_RPR_SRV_AD_DATA_MAX
|
||||
int "Max additional advertisement data to report"
|
||||
default 31
|
||||
range 3 255
|
||||
help
|
||||
Buffer size for the additional advertisement data reported during
|
||||
extended scanning.
|
||||
endmenu
|
||||
|
||||
config BT_MESH_SAR_CFG
|
||||
bool
|
||||
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue