net: syslog: Make sure CONFIG_LOG_IMMEDIATE is not set
The immediate logging option cannot be used with network logging support CONFIG_LOG_BACKEND_NET as that would cause the generated rsyslog messages to be malformed. The UDP packets would only have one byte payloads which is not correct. So make sure that user is not able to select a configuration with immediate mode and network logging. Signed-off-by: Jukka Rissanen <jukka.rissanen@linux.intel.com>
This commit is contained in:
parent
8621e87fb8
commit
cc528d37c2
3 changed files with 10 additions and 1 deletions
|
@ -14,6 +14,11 @@ CONFIG_NET_IF_MCAST_IPV6_ADDR_COUNT=5
|
|||
CONFIG_NET_LOG=y
|
||||
CONFIG_LOG=y
|
||||
|
||||
# Immediate logging does not work with network syslog as it would cause
|
||||
# the sent packet to be malformed (contains only 1 byte data)
|
||||
CONFIG_LOG_IMMEDIATE=n
|
||||
CONFIG_LOG_PROCESS_THREAD=y
|
||||
|
||||
CONFIG_NET_IPV6=y
|
||||
CONFIG_NET_IPV4=y
|
||||
CONFIG_NET_DHCPV4=n
|
||||
|
|
|
@ -12,6 +12,8 @@ LOG_MODULE_REGISTER(net_syslog, LOG_LEVEL_DBG);
|
|||
#include <net/net_core.h>
|
||||
#include <net/net_pkt.h>
|
||||
|
||||
BUILD_ASSERT(IS_ENABLED(CONFIG_LOG_BACKEND_NET), "syslog backend not enabled");
|
||||
|
||||
#define SLEEP_BETWEEN_PRINTS 3
|
||||
|
||||
void main(void)
|
||||
|
|
|
@ -465,9 +465,11 @@ config LOG_BACKEND_XTENSA_OUTPUT_BUFFER_SIZE
|
|||
Buffer is used by log_output module for preparing output data (e.g.
|
||||
string formatting).
|
||||
|
||||
# Immediate mode cannot be used with network backend as it would cause the sent
|
||||
# rsyslog message to be malformed.
|
||||
config LOG_BACKEND_NET
|
||||
bool "Enable networking backend"
|
||||
depends on NETWORKING
|
||||
depends on NETWORKING && NET_UDP && !LOG_IMMEDIATE
|
||||
select NET_CONTEXT_NET_PKT_POOL
|
||||
help
|
||||
Send syslog messages to network server.
|
||||
|
|