drivers: regulator: add regulator shell

Add shell for interacting with regulator devices, to enable
users to test power management settings quickly and verify that their
regulator is functioning as expected. Also allows users to interact with
regulator PMIC devices

Signed-off-by: Daniel DeGrasse <daniel.degrasse@nxp.com>
This commit is contained in:
Daniel DeGrasse 2022-08-23 17:43:38 -05:00 committed by Mahesh Mahadevan
commit 9d7039f9e9
4 changed files with 152 additions and 1 deletions

View file

@ -0,0 +1,142 @@
/*
* Copyright 2022 NXP
*
* SPDX-License-Identifier: Apache-2.0
*/
#include <zephyr/kernel.h>
#include <zephyr/shell/shell.h>
#include <zephyr/drivers/uart.h>
#include <zephyr/drivers/regulator.h>
#if CONFIG_REGULATOR_PMIC
#include <zephyr/drivers/regulator/consumer.h>
#endif
LOG_MODULE_REGISTER(regulator_shell, CONFIG_REGULATOR_LOG_LEVEL);
static int cmd_reg_en(const struct shell *sh, size_t argc, char **argv)
{
struct onoff_client cli;
const struct device *reg_dev;
int ret;
reg_dev = device_get_binding(argv[1]);
if (!device_is_ready(reg_dev)) {
shell_error(sh, "regulator device %s not available", argv[1]);
return -ENODEV;
}
ret = regulator_enable(reg_dev, &cli);
if (ret < 0) {
shell_error(sh, "failed to enable regulator, error %d", ret);
return ret;
}
shell_print(sh, "enabled regulator");
return 0;
}
static int cmd_reg_dis(const struct shell *sh, size_t argc, char **argv)
{
const struct device *reg_dev;
int ret;
reg_dev = device_get_binding(argv[1]);
if (!device_is_ready(reg_dev)) {
shell_error(sh, "regulator device %s not available", argv[1]);
return -ENODEV;
}
ret = regulator_disable(reg_dev);
if (ret < 0) {
shell_error(sh, "failed to disable regulator, error %d", ret);
return ret;
}
shell_print(sh, "disabled regulator");
return 0;
}
#if CONFIG_REGULATOR_PMIC
static int cmd_pmic_set_vol(const struct shell *sh, size_t argc, char **argv)
{
int lvol, uvol, ret;
const struct device *reg_dev;
reg_dev = device_get_binding(argv[1]);
if (!device_is_ready(reg_dev)) {
shell_error(sh, "regulator device %s not available", argv[1]);
return -ENODEV;
}
lvol = atoi(argv[2]) * 1000;
uvol = atoi(argv[3]) * 1000;
shell_print(sh, "Setting range to %d-%d uV", lvol, uvol);
ret = regulator_set_voltage(reg_dev, lvol, uvol);
if (ret < 0) {
shell_error(sh, "failed to set voltage, error %d", ret);
return ret;
}
ret = regulator_get_voltage(reg_dev);
if (ret < 0) {
shell_error(sh, "failed to read voltage, error %d", ret);
return ret;
}
shell_print(sh, "set voltage to %d uV", ret);
return 0;
}
static int cmd_pmic_set_ilim(const struct shell *sh, size_t argc, char **argv)
{
int lcur, ucur, ret;
const struct device *reg_dev;
reg_dev = device_get_binding(argv[1]);
if (!device_is_ready(reg_dev)) {
shell_error(sh, "regulator device %s not available", argv[1]);
return -ENODEV;
}
lcur = atoi(argv[2]) * 1000;
ucur = atoi(argv[3]) * 1000;
shell_print(sh, "Setting range to %d-%d uA", lcur, ucur);
ret = regulator_set_current_limit(reg_dev, lcur, ucur);
if (ret < 0) {
shell_error(sh, "failed to set current, error %d", ret);
return ret;
}
ret = regulator_get_current_limit(reg_dev);
if (ret < 0) {
shell_error(sh, "failed to read current, error %d", ret);
return ret;
}
shell_print(sh, "set current limit to %d uA", ret);
return 0;
}
SHELL_STATIC_SUBCMD_SET_CREATE(pmic_set,
SHELL_CMD_ARG(set_vol, NULL, "Set voltage (in mV)\n"
"Usage: set_vol <device> <low limit (uV)> <high limit (uV)>",
cmd_pmic_set_vol, 4, 0),
SHELL_CMD_ARG(set_current, NULL, "Set current limit( in mA)\n"
"Usage: set_current <device> <low limit (uA)> <high limit (uA)>",
cmd_pmic_set_ilim, 4, 0),
SHELL_SUBCMD_SET_END
);
#endif /* CONFIG_REGULATOR_PMIC */
SHELL_STATIC_SUBCMD_SET_CREATE(regulator_set,
SHELL_CMD_ARG(enable, NULL,
"Enable regulator\n"
"Usage: enable <device>", cmd_reg_en, 2, 0),
SHELL_CMD_ARG(disable, NULL,
"Disable regulator\n"
"Usage: disable <device>", cmd_reg_dis, 2, 0),
#if CONFIG_REGULATOR_PMIC
SHELL_CMD(pmic, &pmic_set, "PMIC management", NULL),
#endif
SHELL_SUBCMD_SET_END
);