drivers: clock_control: Smartbond: Add runtime frequency support
RC32K and RCX low power clocks require runtime calibration to work correctly. Frequency of those clock can differ from chip to chip, one constant value from Kconfig may not be best when low power clock (sourced from RCX or RC32K) is used for system tick. This code modifies global z_clock_hw_cycles_per_sec variable that is used when TIMER_READS_ITS_FREQUENCY_AT_RUNTIME is enabled in Kconfig. Signed-off-by: Jerzy Kasenberg <jerzy.kasenberg@codecoup.pl>
This commit is contained in:
parent
32c04c6b25
commit
82ca880fb9
2 changed files with 31 additions and 0 deletions
|
@ -34,8 +34,13 @@ struct lpc_clock_state {
|
|||
DT_PROP(DT_NODELABEL(rcx), calibration_interval) : \
|
||||
DT_PROP(DT_NODELABEL(rc32k), calibration_interval))
|
||||
|
||||
#ifdef CONFIG_TIMER_READS_ITS_FREQUENCY_AT_RUNTIME
|
||||
extern int z_clock_hw_cycles_per_sec;
|
||||
#endif
|
||||
|
||||
static void calibration_work_cb(struct k_work *work);
|
||||
static void xtal32k_settle_work_cb(struct k_work *work);
|
||||
static enum smartbond_clock smartbond_source_clock(enum smartbond_clock clk);
|
||||
|
||||
static K_WORK_DELAYABLE_DEFINE(calibration_work, calibration_work_cb);
|
||||
static K_WORK_DELAYABLE_DEFINE(xtal32k_settle_work, xtal32k_settle_work_cb);
|
||||
|
@ -59,6 +64,18 @@ static void calibration_work_cb(struct k_work *work)
|
|||
LOG_DBG("RC32K calibration done, RC32K freq: %d",
|
||||
(int)lpc_clock_state.rc32k_freq);
|
||||
}
|
||||
#ifdef CONFIG_TIMER_READS_ITS_FREQUENCY_AT_RUNTIME
|
||||
switch (smartbond_source_clock(SMARTBOND_CLK_LP_CLK)) {
|
||||
case SMARTBOND_CLK_RCX:
|
||||
z_clock_hw_cycles_per_sec = lpc_clock_state.rcx_freq;
|
||||
break;
|
||||
case SMARTBOND_CLK_RC32K:
|
||||
z_clock_hw_cycles_per_sec = lpc_clock_state.rc32k_freq;
|
||||
break;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
#endif
|
||||
}
|
||||
|
||||
static void xtal32k_settle_work_cb(struct k_work *work)
|
||||
|
@ -350,6 +367,19 @@ int z_smartbond_select_lp_clk(enum smartbond_clock lp_clk)
|
|||
}
|
||||
|
||||
if (rc == 0) {
|
||||
#ifdef CONFIG_TIMER_READS_ITS_FREQUENCY_AT_RUNTIME
|
||||
switch (lp_clk) {
|
||||
case SMARTBOND_CLK_RCX:
|
||||
z_clock_hw_cycles_per_sec = lpc_clock_state.rcx_freq;
|
||||
break;
|
||||
case SMARTBOND_CLK_RC32K:
|
||||
z_clock_hw_cycles_per_sec = lpc_clock_state.rc32k_freq;
|
||||
break;
|
||||
default:
|
||||
z_clock_hw_cycles_per_sec = 32768;
|
||||
break;
|
||||
}
|
||||
#endif
|
||||
CRG_TOP->CLK_CTRL_REG = (CRG_TOP->CLK_CTRL_REG & ~clk_sel_msk) | clk_sel;
|
||||
}
|
||||
|
||||
|
|
|
@ -14,3 +14,4 @@ config SOC_SERIES_DA1469X
|
|||
select CLOCK_CONTROL_SMARTBOND
|
||||
select PLATFORM_SPECIFIC_INIT
|
||||
select PM_DEVICE if PM
|
||||
imply TIMER_READS_ITS_FREQUENCY_AT_RUNTIME
|
||||
|
|
Loading…
Add table
Add a link