drivers: clock_control: stm32h7: wait for VOS change
After changing the voltage scale, wait for it to be applied before returning. Signed-off-by: Aurelien Jarno <aurelien@aurel32.net>
This commit is contained in:
parent
f847742c77
commit
6209f4cb6e
1 changed files with 4 additions and 0 deletions
|
@ -253,6 +253,8 @@ static int32_t prepare_regulator_voltage_scale(void)
|
|||
/* Make sure to put the CPU in highest Voltage scale during clock configuration */
|
||||
/* Highest voltage is SCALE0 */
|
||||
LL_PWR_SetRegulVoltageScaling(LL_PWR_REGU_VOLTAGE_SCALE0);
|
||||
while (LL_PWR_IsActiveFlag_VOS() == 0) {
|
||||
}
|
||||
return 0;
|
||||
}
|
||||
|
||||
|
@ -286,6 +288,8 @@ static int32_t optimize_regulator_voltage_scale(uint32_t sysclk_freq)
|
|||
LL_PWR_ConfigSupply(LL_PWR_LDO_SUPPLY);
|
||||
#endif
|
||||
LL_PWR_SetRegulVoltageScaling(LL_PWR_REGU_VOLTAGE_SCALE0);
|
||||
while (LL_PWR_IsActiveFlag_VOS() == 0) {
|
||||
}
|
||||
return 0;
|
||||
}
|
||||
|
||||
|
|