doc: bluetooth: mesh: Fix links in Bluetooth mesh documentation
@ref directive is not working. Replacing it with correct directives. Signed-off-by: Pavel Vasilyev <pavel.vasilyev@nordicsemi.no>
This commit is contained in:
parent
070c93f0d7
commit
32fa349735
1 changed files with 5 additions and 5 deletions
|
@ -32,24 +32,24 @@ To keep a node protected against replay attacks after reboot, it needs to store
|
||||||
the entire RPL in the persistent storage before it is powered off. Depending on
|
the entire RPL in the persistent storage before it is powered off. Depending on
|
||||||
the amount of traffic in a mesh network, storing recently seen sequence numbers
|
the amount of traffic in a mesh network, storing recently seen sequence numbers
|
||||||
can make flash wear out sooner or later. To mitigate this,
|
can make flash wear out sooner or later. To mitigate this,
|
||||||
@ref CONFIG_BT_MESH_RPL_STORE_TIMEOUT can be used. This option postpones
|
:kconfig:option:`CONFIG_BT_MESH_RPL_STORE_TIMEOUT` can be used. This option postpones
|
||||||
storing of RPL entries in the persistent storage.
|
storing of RPL entries in the persistent storage.
|
||||||
|
|
||||||
This option, however, doesn't completely solve the issue as the node may
|
This option, however, doesn't completely solve the issue as the node may
|
||||||
get powered off before the timer to store the RPL is fired. To ensure that
|
get powered off before the timer to store the RPL is fired. To ensure that
|
||||||
messages can not be replayed, the node can initiate storage of the pending
|
messages can not be replayed, the node can initiate storage of the pending
|
||||||
RPL entry (or entries) at any time (or sufficiently before power loss)
|
RPL entry (or entries) at any time (or sufficiently before power loss)
|
||||||
by calling @ref bt_mesh_rpl_pending_store. This is up to the node to decide,
|
by calling :c:func:`bt_mesh_rpl_pending_store`. This is up to the node to decide,
|
||||||
which RPL entries are to be stored in this case.
|
which RPL entries are to be stored in this case.
|
||||||
|
|
||||||
Setting @ref CONFIG_BT_MESH_RPL_STORE_TIMEOUT to -1 allows to completely
|
Setting :kconfig:option:`CONFIG_BT_MESH_RPL_STORE_TIMEOUT` to -1 allows to completely
|
||||||
switch off the timer, which can help to significantly reduce flash wear out.
|
switch off the timer, which can help to significantly reduce flash wear out.
|
||||||
This moves the responsibility of storing RPL to the user application and
|
This moves the responsibility of storing RPL to the user application and
|
||||||
requires that sufficient power backup is available from the time this API
|
requires that sufficient power backup is available from the time this API
|
||||||
is called until all RPL entries are written to the flash.
|
is called until all RPL entries are written to the flash.
|
||||||
|
|
||||||
Finding the right balance between @ref CONFIG_BT_MESH_RPL_STORE_TIMEOUT and
|
Finding the right balance between :kconfig:option:`CONFIG_BT_MESH_RPL_STORE_TIMEOUT` and
|
||||||
calling @ref bt_mesh_rpl_pending_store may reduce a risk of security
|
calling :c:func:`bt_mesh_rpl_pending_store` may reduce a risk of security
|
||||||
vulnerability and flash wear out.
|
vulnerability and flash wear out.
|
||||||
|
|
||||||