sensor: remove sensor value type
Remove the type field from the sensor value structure. All values will have the type previously defined by SENSOR_VALUE_TYPE_INT_PLUS_MICRO. This simplifies the interface, as apps will know what value type to expect. Apps that prefer to use double values can optain them using the sensor_value_to_double function. Change-Id: I3588d74258030eb16c3f89d8eead13cca4606b18 Signed-off-by: Bogdan Davidoaia <bogdan.davidoaia@linaro.org>
This commit is contained in:
parent
662a2d6476
commit
30162aedf1
41 changed files with 44 additions and 253 deletions
|
@ -109,11 +109,6 @@ static int tmp112_attr_set(struct device *dev,
|
|||
|
||||
switch (attr) {
|
||||
case SENSOR_ATTR_FULL_SCALE:
|
||||
|
||||
if (val->type != SENSOR_VALUE_TYPE_INT_PLUS_MICRO) {
|
||||
return -ENOTSUP;
|
||||
}
|
||||
|
||||
/* the sensor supports two ranges -55 to 128 and -55 to 150 */
|
||||
/* the value contains the upper limit */
|
||||
if (val->val1 == 128) {
|
||||
|
@ -133,11 +128,6 @@ static int tmp112_attr_set(struct device *dev,
|
|||
return 0;
|
||||
|
||||
case SENSOR_ATTR_SAMPLING_FREQUENCY:
|
||||
|
||||
if (val->type != SENSOR_VALUE_TYPE_INT_PLUS_MICRO) {
|
||||
return -ENOTSUP;
|
||||
}
|
||||
|
||||
/* conversion rate in mHz */
|
||||
cr = val->val1 * 1000 + val->val2 / 1000;
|
||||
|
||||
|
@ -212,7 +202,6 @@ static int tmp112_channel_get(struct device *dev,
|
|||
}
|
||||
|
||||
uval = (int32_t)drv_data->sample * TMP112_TEMP_SCALE;
|
||||
val->type = SENSOR_VALUE_TYPE_INT_PLUS_MICRO;
|
||||
val->val1 = uval / 1000000;
|
||||
val->val2 = uval % 1000000;
|
||||
|
||||
|
|
Loading…