sanitycheck: capture fails correctly on qemu crashes

We still have cases where qemu crashes are not being correctly captured
in the on-screen summary, however they are captured in the final
generated report.

Fixes #26679

Signed-off-by: Anas Nashif <anas.nashif@intel.com>
This commit is contained in:
Anas Nashif 2020-07-15 22:44:24 -04:00
commit 06052927be

View file

@ -840,8 +840,6 @@ class QEMUHandler(Handler):
timeout_time = time.time() + 30
else:
timeout_time = time.time() + 2
else:
logger.debug("got nothing from harness")
line = ""
handler.record(harness)
@ -850,15 +848,17 @@ class QEMUHandler(Handler):
logger.debug("QEMU complete (%s) after %f seconds" %
(out_state, handler_time))
handler.set_state(out_state, handler_time)
if out_state == "timeout":
handler.instance.reason = "Timeout"
handler.set_state("failed", handler_time)
elif out_state == "failed":
handler.instance.reason = "Failed"
elif out_state in ['unexpected eof', 'unexpected byte']:
handler.set_state("failed", handler_time)
elif out_state in ['unexpected eof', 'unexpected byte']:
handler.instance.reason = out_state
handler.set_state("failed", handler_time)
else:
handler.set_state(out_state, handler_time)
log_out_fp.close()
out_fp.close()
@ -936,10 +936,9 @@ class QEMUHandler(Handler):
if os.path.exists(self.pid_fn):
os.unlink(self.pid_fn)
logger.debug(f"return code from qemu: {self.returncode}")
if self.returncode != 0:
if self.returncode != 0 or not harness.state:
self.set_state("failed", 0)